Automatic drawing ballooning: what is detected, what is linked and what waits

Numbering the requirements of a PDF drawing is the easy half of ballooning. The half that decides whether the inspection can be trusted is the link between each balloon and the geometry it refers to — and what the software does when it cannot prove that link.

A balloon is a promise to account for a requirement

A balloon number on a drawing says: this requirement will appear in the report, under this number, with a result. The inspection plan, the report and the customer's review all follow the numbers. Ballooning by hand is slow and error-prone mainly for one reason — a requirement that was not numbered is a requirement nobody measures, and nobody notices.

Automatic ballooning therefore has two jobs. The first is to find every requirement on the sheet. The second, which matters more for a scan-based inspection, is to know which face, hole or edge of the CAD model each number refers to, because a number that points at the wrong feature produces a confident wrong result.

What is read from the PDF

A vector PDF carries its own geometry and text, and Ai-Inspect's Drawing Inspector reads both rather than a picture of them: dimension lines with their arrowheads and leaders, the dimension text with its tolerance, hole callouts, feature control frames with their datum references and modifiers, datum flags, and profile frames with unequal zones. Scanned drawings are supported as well. General-tolerance notes such as ISO 2768 are read from the drawing itself, so an untoleranced dimension gets the tolerance class the title block states.

  • Dimensions with plus / minus and limit tolerances
  • Hole callouts split into their parts: through, counterbore, countersink, depth, thread
  • Feature control frames: characteristic, zone, modifiers and datum references
  • Datum flags and the faces they are attached to
  • General-tolerance note of the sheet (ISO 2768 class)

Your customer's numbers are kept

Many drawings arrive already ballooned by the customer. Renumbering them would break the link to the customer's own inspection sheet, so detected balloon rings are adopted verbatim — the number in the ring becomes the number in the report. A drawing without balloons is numbered automatically. Repeated features share a base number with an instance suffix (5_1, 5_2 …), so eight identical holes are eight rows under one balloon.

A link needs evidence

To link a balloon to the model, the drawing's views, sections and details are registered against the CAD's own hidden-line projection — the software draws the model the way the drafter did and overlays the two, tilted sheets included. A requirement whose leader, arrowhead or datum flag lands on a projected edge or face is linked automatically, and the link shows the evidence it was made from.

A requirement that only matches a CAD dimension by its value is a different case. A 12.0 on the drawing and a 12.0 on the model may or may not be the same feature; parts are full of repeated values. Such a balloon is not linked automatically. It becomes a 'confirm the candidate' task: the software proposes the feature, and the measurement waits for the operator's click on the model.

From the ballooned drawing to a program and a report

The linked plan is written out as a measurement program, one step per requirement, and runs on the scan. After the run, the Measurement Copilot lists the balloons that are still open — the candidates that wait for confirmation, the features without scan coverage, the datums that could not be established — and walks through them one at a time. Each decision is recorded into the program, so the second part of the series starts with those answers in place.

The report is ordered by balloon number and includes a coverage page that checks the measured rows against the balloons of the drawing. A balloon that was never measured is listed there by number. That page is the answer to the oldest ballooning failure: the requirement nobody noticed.

Questions this article answers

Yes. A balloon number, a nominal or a tolerance can be edited in the report table; the edit is written back to the measurement data and into the recorded program.

No. The optional cloud layer can review the drawing, but its suggestions pass through the same geometric gates as everything else. A link without geometric evidence still waits for the operator.

No. Recognition runs on the workstation. The drawing is sent to a cloud model only when the optional Cloud AI module is licensed and switched on.

See it on your own parts

Bring a drawing, a CAD model and a scan — we will run the inspection with you in a guided demo.