Automatic drawing ballooning: what is detected, what is linked and what waits
Numbering the requirements of a PDF drawing is the easy half of ballooning. The half that decides whether the inspection can be trusted is the link between each balloon and the geometry it refers to — and what the software does when it cannot prove that link.
Datum reference frames on a 3D scan: building A | B | C from measured features
A best-fit alignment makes a good colour map and a poor datum frame. How a datum reference frame is built from the measured datum features of a scan, why one frame must serve position, coordinates and profile, and what should happen when a datum cannot be established.
Flatness and straightness of a 1.6 m welded frame from a 3D scan
A worked example: a welded frame about 1.6 m long with coplanar mounting pads, an overall flatness, a flatness per area and a straightness per length on its rails. How the scan is prepared, how the grid is laid across separate pads and what the report shows.
Wall thickness on bent sheet metal: reading thinning from a scan
Sheet metal thins where it is bent, and the drawing usually states a minimum wall. How the thickness of a formed part is read from a two-sided scan — on the flanges and around the bends — and why springback does not change the reading.
From a PC-DMIS or CAMIO program to a scan report, step by step
A practical walk through running a CMM program on a 3D scan: exporting DMIS, importing it, checking the frame, running on the scan, closing the open items and exporting the report — with the checks to make at each step.
A first article inspection report from a 3D scan: building the characteristic table
A first article inspection is an exercise in accountability: every characteristic on the drawing, numbered, with a requirement and a result. How that table is built from a ballooned drawing and a scan, what to do with the rows a scan cannot fill, and where the AS9102 forms begin.
Offline AI in quality control: what a local model does on an inspection workstation
Drawings and CAD models are controlled data, and many inspection rooms have no internet connection at all. What an AI assistant can do when the model runs on the workstation itself, what it is deliberately not allowed to do, and how an optional cloud model fits in.
Plane Grid: flatness and straightness per length on large faces
How a numbered grid turns a scanned face into flatness, flatness per area and straightness per length — the callouts that welded frames and sheet-metal panels actually carry — and why a point without scan under it is reported as N/A, never as a value.
Wall thickness from a scan: three rays per point
Measuring the thickness of a wall from a 3D scan sounds simple until the far face is oblique, the scan covers one side only or the CAD nominal is not where the part is. The Wall Thickness Grid casts three rays per grid point and refuses, per point, whatever cannot be proven.
Profile with unequal zones: U and UZ, the material side and the plot
A surface profile of 0.6 Ⓤ 0.4 is not a ±0.3 zone. How ASME's U modifier and ISO's UZ offset are evaluated on a scan, why the sign must come from the material side of the CAD body, and what the profile plot shows.
The Measurement Copilot: precision by refusal
After a program run, some balloons were not measured. The Copilot shows which, why, and what the operator can do about each — proposing candidates from a closed set, asking for a pick in 3D and re-running through the measurement engine. It never measures on its own and never confirms for you.
GD&T on 3D scans: how geometric tolerances are evaluated on a mesh
What changes when flatness, position or profile are evaluated on a scanned mesh instead of CMM probe hits — and what the software must guarantee so the result is defensible.
Running existing DMIS CMM programs on a 3D scan
Why a DMIS program is really a measurement plan, what has to be reconstructed to execute it on scan data, and where the translation must refuse rather than guess.
Automated inspection from a PDF drawing: ballooning, planning and gated measurement
How a drawing becomes an inspection plan — reading dimensions and feature control frames from a PDF, linking them to the CAD model, and deciding what can be measured automatically.
Choosing a 3D scanner for quality control: what actually matters
Stated accuracy, resolution, part size, surface finish and workflow fit — a practical checklist for selecting a scanner for metrology, and why the software should not lock you to one brand.
Frequently asked questions
Three things in one suite: it reads the engineering drawing itself (AI auto-ballooning and a gated auto-inspection), it runs your existing CMM DMIS programs directly on a 3D scan, and everything — including the AI assistant — works fully offline. All of it scanner-agnostic, with perpetual licensing.
Measurement accuracy is determined by your scanner — its stated accuracy, resolution and the quality of the scan (coverage, noise, calibration) — not by the software. Ai-Inspect evaluates exactly the geometry the scan contains and will not improve or degrade it. What the software guarantees is methodological: fits and GD&T follow ASME Y14.5 / ISO 1101, every nominal comes from the CAD model, and anything that cannot be proven on the scan (missing coverage, unverified datum frames) is refused and routed to manual review instead of being estimated.
Nominal CAD in STEP, IGES and STL; scans in STL, PLY, OBJ, VTK and VTP. Drawings as PDF (vector or scanned). Reports export to PDF, CSV, Excel and HTML, plus a PAS CMM CSV that loads directly into PAS.
No. Ai-Inspect is scanner-agnostic — any device that exports a mesh (STL, PLY, OBJ) works, including Creaform, GOM, Shining3D, Artec and others. The built-in Scan Tool can also align and merge multiple partial scans into one part.
You load the PDF drawing and Ai-Inspect detects the dimensions, tolerances, GD&T frames and datums, balloons them automatically and builds an inspection plan. High-confidence requirements are measured automatically; anything ambiguous is routed to the Measurement Copilot with an explicit reason — accuracy by refusal, never by guessing.
Yes. The DMIS translator parses PAS, CAMIO and PC-DMIS dialects, reconstructs the datum alignments, synthesizes measurement points where the program has none, and replays the program on the scan. It has been validated end-to-end against real CMM result files.
No. The AI assistant runs locally on a model we match to your hardware and workload, and all CAD/scan/drawing data stays on your machine — Ai-Inspect runs fully offline / air-gapped. A cloud AI provider (Anthropic Claude) exists as an optional, separately licensed module that requires explicit opt-in.
The interface is fully localized in Hebrew, English and Russian — including the help center and the AI assistant, which understands measurement commands in all three languages.
Windows 10/11 64-bit, an OpenGL 3.3+ GPU, 16 GB RAM recommended. We size the local AI model to the workstation you already have — from a compact model on a standard PC to a larger one on a GPU-equipped station. Tell us your hardware and we will tailor the install.
Licences are perpetual and machine-locked, per inspection station. After installing, the start-up screen shows your machine code; send it to us and we issue a licence file (.lic) that also carries the modules you licensed — Inspect, Analysis (Plane Grid, Wall Thickness Grid, Section Profile, 2D editor), Drawing Inspector and Cloud AI. Adding a module later is a new file or a module code, no reinstall.
Updates ship as a compact update installer (~300 MB) that replaces only the application files — your license, language, settings and the local AI model stay untouched. Update installs take about a minute.
Yes. Record the inspection once as a macro, then either replay it per part or point Batch mode at a folder of scans — each part is auto-aligned, measured and reported (PDF/CSV/PAS) unattended. Replay re-measures on the new scan; it is a true measurement program, not a stored-numbers playback.
Yes — request a demo from the contact page and our team will arrange a guided walkthrough on your own parts and drawings, plus a trial license.
Contact us for a written quote — it depends on the modules you need and the number of stations, and it is where our prices appear; the website carries none. Licences are purchased outright (perpetual, machine-locked), with optional annual service and updates, multi-station terms and site agreements.
The feature is not estimated. Ai-Inspect checks scan coverage point by point; a feature without enough surface under it is reported as N/A with the reason (missing coverage, partial arc, unverified datum), the balloon is marked in red on the model after the program run, and the Measurement Copilot lists it as an open task — rescan, pick it manually, or document it as a manual check. The report shows exactly what was measured and what was not.
You assign datum letters to measured elements — planes, cylinders, circles, points, slots — and Ai-Inspect builds the datum reference frame the way a CMM program does (3-2-1 and variants). Refine-to-Datums then corrects the alignment to that frame, and the same frame is used for true position, coordinate rows and profile — so a position in the datum frame matches the same position measured in a coordinate system built from those datums.
Yes. The Plane Grid places a numbered grid on any planar face (whole face, regions or a contour strip along the edge), projects the scan onto it and reports flatness, flatness per area and straightness per line and per length — with sketches and a full point table in the PDF. The Wall Thickness Grid reads thickness point by point through the material against the CAD nominal. Both run as recorded steps on every part; the part size is limited by your scanner, not by the software.
Yes, when the scan covers both sides of the wall. The Wall Thickness Grid places a numbered grid on the face and casts three rays per point: the near surface, the far surface through the material and the CAD nominal on the same ray. A one-sided scan, an oblique far face or a missing CAD back face is refused per point with the reason — no thickness is ever estimated. Tolerances can be one-sided (minimum wall only), and Cp/Cpk are reported when both limits exist.
The screen you land on after a program run. It lists every balloon with its status and the engine's reason, groups the open items into datums, gaps and FAIL review, and walks you through them one task at a time — proposing candidates from a closed set, asking for a pick in 3D when needed and re-running the step through the same measurement engine. It never measures on its own and never confirms a candidate for you. Finishing produces the report and the extended program.
Yes — Surface Best-Fit. Click the CAD faces that matter (whole STEP faces, or crease-bounded regions on an STL), lock any degree of freedom and compute. The fit is refined only on those faces; a selection that leaves an axis free is refused with the free axes named rather than guessed. The result is stored as a coordinate system, the measured elements follow the scan, and the step replays in the program.
Yes. Results are ordered by balloon number (with instance suffixes such as 5_1, 5_2), exported as ballooned PDF, Excel, CSV and HTML, and as a PAS CMM CSV. The report designer lets you edit nominals, tolerances, balloon numbers, type and instrument columns — edits sync back to the measurement database and to the recorded program.
Yes. Offline mode synthesizes a scanner-like mesh from the nominal CAD at the resolution you choose. You program the full inspection — elements, GD&T, sections, plane grids, report — on that synthetic scan, then run the same program on the real part when it comes off the machine.
Form (flatness, straightness, circularity, cylindricity), orientation (perpendicularity, parallelism, angularity), location (position, concentricity, symmetry), profile of a line and of a surface, circular and total runout — with multi-datum reference frames, MMC/LMC bonus and datum shift, per ASME Y14.5 and ISO 1101. Flatness uses an exact minimum-zone solution.
After a program run, the Measurement Copilot shows which balloons were measured, which were refused and why, and walks the operator through the open items one at a time — proposing the next element, asking for a pick in 3D when needed, re-running the step and explaining the result. It never measures on its own: every value comes from the same measurement engines, and the assistant works through a closed set of actions. The chat agent can also plan and execute complete measurement tasks from a sentence, in Hebrew, English or Russian.
It depends on the tolerances and on the scanner. A scan captures whole surfaces at once and feeds GD&T, colour maps, sections and grids directly; features whose tolerance is tighter than what the scanner can resolve still belong on a touch probe, and Ai-Inspect refuses them with a 'resolution limited' reason rather than reporting a number. Many teams run both — the same DMIS program on the CMM and on the scan — and let the refusals decide what stays on the CMM.