Four stages on one screen
The Drawing Inspector works in four stages — drawing, recognition, link to the model, program and report — with an action panel that changes with the stage. Vector PDFs are read from their own geometry and text; scanned drawings are supported as well.
- Dimensions and tolerances, hole callouts included
- Feature control frames with their datum references and modifiers
- Datum flags and unequal profile zones
- General-tolerance notes (ISO 2768) read from the drawing
Your customer's balloon numbers stay
When the drawing already has balloon rings, they are detected and adopted verbatim, so the report uses the numbers your customer knows. A drawing without balloons is numbered automatically, and every balloon keeps a record of how it was detected.
From a balloon to a measurement
Views, sections and details of the drawing are registered against the CAD's hidden-line projection, tilted sheets included. A balloon whose feature is identified this way is linked automatically and shows the evidence for the link.
A balloon that only matches a CAD dimension by its value is not linked automatically; it becomes a 'confirm the candidate' task. The linked plan is then written out as a measurement program.
Offline by default
Recognition runs on the workstation. An optional cloud AI layer can review the drawing; it is a separately licensed module that has to be enabled, and its suggestions pass through the same geometric gates as everything else.