Every characteristic gets a number
The Drawing Inspector reads the PDF drawing and detects dimensions, tolerances, feature control frames and datum flags. If the drawing already carries the customer's balloon numbers they are adopted as they are; otherwise the drawing is ballooned automatically. General-tolerance notes such as ISO 2768 are read from the drawing itself.
Each number is linked to geometry before it is measured
A requirement becomes an automatic measurement only when its link to the CAD geometry is proven: the drawing view is registered against the CAD's own projection and the feature is identified there. A requirement that matches by value alone becomes a task for the operator to confirm. Nothing is measured on a guess.
What the report contains
The report is ordered by balloon number, so it reads in the same order as the ballooned drawing.
- One row per balloon, with instance suffixes such as 5_1, 5_2 for repeated features
- Requirement, nominal, tolerance, measured value, deviation and status
- Rows that were not measured stay in the report as N/A with the reason
- A coverage page that checks the report against the balloons of the drawing
- PDF, Excel, CSV and HTML export
Where AS9102 comes in
AS9102 defines three forms. Form 1 (part number accountability) and Form 2 (materials, special processes and functional tests) describe the part and its supply chain and are completed by your organisation. Form 3 (characteristic accountability) lists each design characteristic with its requirement and result — this is the data Ai-Inspect produces.
The Excel and CSV exports carry that data row by row, for transfer into your own Form 3 template or quality system. Characteristics the scan cannot support, and those verified by other means, stay visible as open rows to be completed with the instrument that measured them.