Solutions

Wall thickness measurement from a 3D scan

When a scan covers both sides of a wall, its thickness can be read at every point of a numbered grid — on plates, bent sheet metal, castings, pipes and cones — and checked against the thickness the CAD model defines at the same place.

Wall Thickness Grid sketch — thickness at every grid point against the CAD nominal, pass / fail coloured

Three rays per grid point

The Wall Thickness Grid places a numbered lattice on a CAD face. At every point one ray finds the near surface on the scan, a second continues through the material to the far surface, and a third reads the CAD nominal along the same line.

The thickness is the distance between the two scan hits. The nominal comes from the drawing value or from face to face on the CAD, and is computed analytically on cylinders and cones.

Tolerances and statistics

The result is a table with a row per point and summary rows for the face, and a page in the PDF report.

  • One-sided tolerances — a minimum wall only — as well as two-sided ones
  • Min, max and mean rows plus a row per point, each with a stable balloon number
  • Cp and Cpk when both limits exist
  • Grid sketch coloured by pass / fail, and a histogram of the thickness
  • Pipe walls read from both sides on cylinders and cones

Where a thickness is not reported

A point is refused, with the reason, when the scan covers one side only, when the far face is too oblique to the ray, or when the CAD has no back face there. No thickness is estimated from a single surface. Refused points stay in the table as N/A, so the report shows how much of the wall was verified.

The same grid on every part

The grid is a recorded step of the program. On the next part of the series the same points carry the same balloon numbers, and the point table can be exported as CSV to follow a point from part to part.

Questions and answers

Yes. Thickness is the distance between two measured surfaces, so both have to be in the scan, in one coordinate system.

Yes. On cylinders and cones the lattice wraps around the face and the nominal is computed analytically.

The Wall Thickness Grid belongs to the Analysis add-on, together with the Plane Grid and the Section Profile.

See it on your own parts

Send us a note and we will run a live, remote demo on your kind of parts — your drawing, your CAD model and a scan.

  • Live and remote, at a time that suits your time zone
  • On your own drawing, CAD model and scan
  • A reply within one business day